Standard Thermocouple for Primary Labs, Model 1600
|
|
|

Type R & S Standard Thermocouple with premium grade wire and gas-tight assembly
0°C to 1600°C (32°F to 2912°F)No Intermediate JunctionsReference Junctions Fit Into Zeref
|
|
 |
|
|
|
|
 |
|
Rosemount 162CE SPRT
|
|
|

-200°C to 661°C (1221°F) Typical wait time on the 162CE is 24 weeks but we have them IN STOCK
Accuracy of 0.001°C Resistance value of 25.5Ω Long term drift of only 0.01°C/year Self-heating Rugged, shatter-proof metal sheath
|
|
 |
|
|
|
|
 |
|
OBERON R - Blackbody Source for High Temperature
|
|
|

BlackBody Fixed Point System
450°C to 1090°C (1994°F) Advanced Heat Pipe Technology High Temperature Furnace for Aluminum, Silver, Gold or Copper Blackbody Fixed-Point Cells
|
|
 |
|
|
|
|
 |
|
SPRT (Standard Platinum Resistance Thermometer), Model 670
|
|
|

Our Best Standard Platinum Resistance Thermometer
-200°C to 670°C (1238°F)
- Resistance Value (°C): 25.5ΩRo
- Resistance Ratio: WGA>1.11807 as required by ITS-90
- Sensitivity: 0.1Ω/°C
- Long term drift from 0.001°C/year
- Calibration (UKAS): Water T.P., Tin F.P., Zinc F.P., Aluminum F.P. with print-out of temperature at W-intervals of 0.01
|
|
 |
|
|
|
|
 |
|
Calibration Baths, Hydra Series Oil Baths
|
|
|

New Range of Stirred Liquid Baths, Superior stability and vertical uniformity
-80°C to 300°C (572°F)
- Parallel Tube Action Liquid flows up the rear volume of the bath and down the working volume. This action creates very small vertical and axial gradients. Enabling the smallest overall uncertainties
- Heating All heating is outside the container. By using a large area nickel foil heater the complete bath wall is heated uniformly
- Cooling The cooling is built-in and also surrounds the calibration volume creating a low temperature ambient in which the heater can function efficiently
- Wider Temperature Range A unique system removes the coolant from around the calibration volume above ambient and lets the bath heat up to 125°C (121°C is a key sterilization temperature)
- Commercial Grade Chillers The chillers are 1/3 horse power commercial grade units (not cheaper domestic grade as used by some manufacturers)
- Stability Better than ±0.01°C over the complete temperature range
- Calibration Depth Double the depth of some baths, the Hydra Range has up to 300mm depth of immersion
- Circular Design The circular design eliminates cold corners in tank-shaped baths
- Fast Cool Down Goes from ambient to -80°C in 150 min
|
|
 |
|
|
|
|
 |
|
Thermocouple Reference, Model 842 Ambient TC Referencing System
|
|
|

Environmental Referencing Unit Ideal for Systems with wide Swings in Ambient Operating Range The Perfect System for Aircraft Engine Test Stands
- Waterproof Cased Ambient Temperature
- Thermocouple Referencing System
- Large Capacity up to 100 Thermocouples
- Wide Ambient Range
- Approved for Power Station Use
- Rack Mounted Ambient Temperature Referencing System
- 19" Rack Mounting
|
|
 |
|
|
|
|
 |
|
Spherical Blackbody Source, Model 878 Cyclops
|
|
|

Our most stable Black Body Source
150°C to 1300°C (2372°F) Option to convert to Traditional Spherical Thermocouple Calibration Furnace
- Spherical Blackbody Source
- Wide Temperature Range
- Can be Adapted for Thermocouple Calibration 877 Saturn
|
|
 |
|
|
|
|
 |
|
SPRT (Standard Platinum Resistance Thermometer), Model 909
|
|
|

Working S.P.R.T.s
-65°C to 300°C (572°F)
- 3 Probe Lengths to choose from
- Wide Range
- Proven Design
- Nominal Diameter 7.5mm
|
|
 |
|
|
|
|
 |
|
Calibration Bath, Model 915 Parallel Tube Liquid Bath
|
|
|

Large Volume Fluid Bath with Optional External Single and Two Stage Chillers
As low as -65°C to 300°C
|
|
 |
|
|
|
|
 |
|
Ice Point Reference, Model 938
|
|
|

Thermocouple Cold Junction Reference Unit
0°C (32°F) Accuracy of ± 0.03°C
- Thermocouple Referencing to ISO9000 at 0°C, in ambients of up to 65°C or elevated reference temperature
- References up to 100 Thermocouples
- Direct Replacement for other Units
|
|
 |